    Brand Name : GSKA
    Model Number : JP-P175HE
    Price : Negotiable
    Delivery Time : 3-5 days on receipt of official sales contract
    Payment Terms : L/C,D/P,D/A, Alipay, West Union, TT. Cash,Paypal
    Supply Ability : 500 pieces per Month
    • Product Details
    • Company Profile

    185 kVA / 148 kW Perkins Diesel Generator , LL3014H , 148 KW


    1. Standby power: 148.0 KW , 60 Hz

    2. Engine Make & Model: Perkins 1306-E87T215

    3.Alternator Model: LL3014H

    4.Circuit Breaker Type: 3 Pole MCCB

    5.Type: Electronic Governing

    6.Class: ISO 8528 G2

    7.Compression Ratio: 17.2:1

    8.Displacement: l (cu.in) 8.7 (530.9)

    9.Bore/Stroke: mm (in) 116.6 (4.6)/135.9 (5.4)

    10.Moment of Inertia: kg m² (lb. in²) 1.54 (5266)


    185 kVA 148 kW Perkins Diesel Generator , LL3014H


    Output Ratings

    Generating Set Model


    * P175HE Prime* Standby*

    380-415V, 50 Hz

    - -

    - -

    480V, 60 Hz

    169.0 kVA 185.0 kVA

    135.2 kW 148.0 kW

    • Refer to ratings definitions on page 4.

    Ratings at 0.8 power factor.


    Technical Data

    Engine Make & Model:

    Perkins 1306-E87T215

    Alternator Model:

    LL3014H

    Base Frame Type:

    Heavy Duty FabriCAT-parts-partsed Steel

    Circuit Breaker Type:

    3 Pole MCCB

    Frequency:

    50 Hz 60 Hz

    Engine Speed: RPM

    - 1800

    Fuel Tank Capacity: litres (US gal)

    350 (92.5)

    Fuel Consumption: P160H l/hr (US gal/hr)

    - 41.8 (11.0)

    Fuel Consumption: P175HE l/hr (US gal/hr)

    - 43.7 (11.5)

    P160H / P175HE


    Engine Technical Data


    Physical Data


    Manufacturer: Perkins

    Model: 1306-E87T215

    No. of Cylinders/Alignment: 6 / In Line

    Cycle: 4 Stroke

    Induction: Turbocharged

    Cooling Method: Water Governing

    Type: Electronic Governing

    Class: ISO 8528 G2

    Compression Ratio: 17.2:1

    Displacement: l (cu.in) 8.7 (530.9)

    Bore/Stroke: mm (in) 116.6 (4.6)/135.9 (5.4)

    Moment of Inertia: kg m² (lb. in²) 1.54 (5266)

    Engine Electrical System:

    -Voltage/Ground: 24/Negative

    -Battery Charger Amps: 45

    Weight: kg (lb)

    - Dry: 671 (1479)

    - Wet: 698 (1539)


    Air System 50 Hz 60 Hz


    Air Filter Type: Replaceable

    Element Combustion Air Flow:m³/min (cfm)

    -Standby: - 18.0 (636)

    -Prime: - 20.6 (727)

    Max. Combustion Air Intake

    Restriction: kPa (in H2O) 6.2 (24.9)

    Radiator Cooling Air Flow:m³/min (cfm) 414.0 (14620)

    External Restriction to Cooling Air Flow: Pa (in H2O) 125 (0.5)


    Cooling System 50 Hz 60 Hz


    Cooling System Capacity:l (US gal) 36.8 (9.7)

    Water Pump Type: Centrifugal

    Heat Rejected to Water & Lube Oil: kW (Btu/min)

    -Standby: - 88.5 (5033)

    -Prime: - 79.4 (4515)

    Heat Radiation to Room:

    kW (Btu/min)

    -Standby: - 52.0 (2957)

    -Prime: - 45.1 (2565)

    Radiator Fan Load: kW (hp) 12.0 (16.1)

    Cooling system designed to operate in ambient conditions up to 50°C (122°F).


    Performance 50 Hz 60 Hz


    Engine Speed: RPM 1800

    Gross Engine Power: kW (hp)

    -Standby: - 171.5 (230.0)

    -Prime: - 156.0 (209.0)

    BMEP: kPa (psi)

    -Standby: - 1313.0 (190.5)

    -Prime: - 1194.0 (173.2)

    Regenerative Power: kW 28.6


    LubriCAT-parts-partsion System


    Oil Filter Type: Spin-On, Full Flow

    Total Oil Capacity l (US gal): 26.4 (7.0)

    Oil Pan l (US gal): 22.7 (6.0)

    Oil Type: API CG4 15W-40

    Cooling Method: Water


    Fuel System


    Fuel Filter Type: Replaceable Element Recommended

    Fuel: Class A2 Diesel

    Fuel Consumption: l/hr (US gal/hr)

    110% 100% 75% 50%

    Load Load Load Load

    P160H


    50 Hz - - - -

    60 Hz 43.7 (11.5) 41.8 (11.0) 34.7 (9.2) 24.9 (6.6)

    P175HE


    50 Hz - - -

    60 Hz 43.7 (11.5) 37.0 (9.8) 26.9 (7.1)


    (based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869, Class A2)


    Exhaust System 50 Hz 60 Hz


    Silencer Type: Level 1

    Silencer Model & Qty: SD100 (1)

    Pressure Drop Across

    Silencer System: kPa (in Hg) 8.70 (2.569)

    Silencer Noise Reduction Level: dB 10

    Max. Allowable Back Pressure: kPa (in. Hg) 10.7 (3.2)

    Exhaust Gas Flow: m³/min (cfm)

    -Standby: - 43.0 (1519)

    -Prime: - 47.2 (1667)

    Exhaust Gas Temperature: °C (°F)

    m³/min (cfm)

    -Standby: - 407 (765)

    -Prime: - 322 (611)

    P160H / P175HE


    Alternator Performance Data


    Data Item

    50 Hz 60 Hz

    480/277V

    240/139V

    380/220V

    220/110V

    240/120V

    208/120V

    230/115V

    440/254V

    220/127V


    Motor Starting Capability* kVA

    420

    282

    330

    309

    363

    Short Circuit Capacity** %

    -

    -

    -

    -

    -

    Reactances: Per Unit

    Xd X'd X''d

    2.610


    0.090


    0.053

    4.140


    0.140


    0.083

    3.480


    0.120


    0.070

    3.760


    0.130


    0.076

    3.110


    0.100


    0.063


    Reactances shown are applicable to prime ratings

    • Based on 30% voltage dip. Improved motor starting capability is available with optional Permanent Magnet generator or AREP excitation.

    ** With optional Permanent Magnet generator or AREP excitation.


    Alternator Technical Data


    Physical Data Operating Data

    Manufacturer:FG WILSON

    Overspeed: RPM 2250

    Model: LL3014H

    Voltage Regulation (steady state) (%): + /- 0.5

    No. of Bearings: 1

    Wave Form NEMA = TIF: 50

    Insulation Class:H

    Wave Form IEC = THF: 2.0%

    Winding Pitch Code: 2/3 - 6

    Total Harmonic Content LL/LN: 4.0%

    Wires: 12

    Supression is in line with European Standard

    Radio Interference: EN61000-6

    Ingress Protection Rating: IP23

    Radiant Heat: kW (Btu/min)

    -50 Hz: -

    -60 Hz: 11.0 (626)

    Excitation System: SHUNT

    AVR Model: R230

    P160H / P175HE


    Technical Data


    3 Phase Ratings and Performance at 50 Hz, -RPM

    3 Phase Ratings and Performance at 60 Hz, 1800 RPM



    Voltage Prime Model Standby Model Voltage Prime Model Standby Model

    P160H P175HE

    kVA kW

    kVA kW


    kVA kW

    kVA kW



    480/277V

    169.0 135.2

    185.0 148.0



    220/127V

    169.0 135.2

    185.0 148.0



    380/220V

    168.0 134.4

    185.0 148.0



    240/120V

    169.0 135.2

    185.0 148.0



    230/115V

    169.0 135.2

    185.0 148.0



    440/254V

    169.0 135.2

    185.0 148.0



    220/110V

    168.0 134.4

    185.0 148.0



    208/120V

    169.0 135.2

    185.0 148.0


    Definitions

    Standby Rating

    These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).


    Prime Rating

    These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.


    Standard Reference Conditions

    Note: Standard reference conditions 27°C (80°F) Air Inlet Temp, 152.4m (500ft) A.S.L. 60% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.



    Weights and Dimensions


    Weights: kg (lb) Dimensions: mm (in)



    Net (+ lube oil)


    1865 (4112)


    Length


    2960 (116.5)

    Wet (+ lube oil & coolant)

    1902 (4193)

    Width

    1003 (39.5)

    Fuel, lube oil & coolant

    2197 (4844)

    Height

    1718 (67.6)


    General Data


    Documents

    A full set of operation and maintenance manuals, circuit wiring diagrams, and commissioning/fault finding instruction leaflets.



    Generating Set Standards

    The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, VDE 0530, NEMA MG-1.22.


    Warranty

    All equipment carries full manufacturer's warranty.

    Quality 185 kVA / 148 kW Perkins Diesel Generator , LL3014H , 148 KW for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangdong ALI Testing Equipment Co,.Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)