Sign In | Join Free | My himfr.com
Home > Perkins Diesel Generator >

750 kVA 60 Hz Perkins Diesel Generators , 3 Pole ACB / MCCB

    Buy cheap 750 kVA 60 Hz Perkins Diesel Generators , 3 Pole ACB / MCCB from wholesalers
     
    Buy cheap 750 kVA 60 Hz Perkins Diesel Generators , 3 Pole ACB / MCCB from wholesalers
    • Buy cheap 750 kVA 60 Hz Perkins Diesel Generators , 3 Pole ACB / MCCB from wholesalers
    • Buy cheap 750 kVA 60 Hz Perkins Diesel Generators , 3 Pole ACB / MCCB from wholesalers

    750 kVA 60 Hz Perkins Diesel Generators , 3 Pole ACB / MCCB

    Ask Lasest Price
    Brand Name : GSKA
    Model Number : JP-P800E1
    Price : Negotiable
    Delivery Time : 3-5 days on receipt of official sales contract
    Payment Terms : L/C,D/P,D/A, Alipay, West Union, TT. Cash,Paypal
    Supply Ability : 500 pieces per Month
    • Product Details
    • Company Profile

    750 kVA 60 Hz Perkins Diesel Generators , 3 Pole ACB / MCCB


    1, Engine Make & Model: Perkins 4006TAG2A

    2,Generating Set Model: P800E1

    3,Alternator Model: LL7024L

    4, Circuit Breaker Type: 3 Pole ACB/MCCB

    5, Frequency: 50 Hz / 60 Hz

    6,Cycle: 4 Stroke

    7, Engine Speed: 1500rpm/1800rpm

    8, Cooling Method: Turbo, Water/Air cooling

    9, Governing Type: Electronic

    10, Output Type: AC Three Phase

    10, No.of Cylinders/Alignment: 6 / In Line

    11,Base Frame Type: Heavy Duty FabriCAT-parts-partsed Steel


    750 kVA 60 Hz Perkins Diesel Generators , 3 Pole ACB / MCCB

    Output Ratings

    Generating Set Model

    * P800E1

    Prime* Standby*

    380-415V, 50 Hz

    730.0 kVA 800.0 kVA

    584.0 kW 640.0 kW

    480V, 60 Hz

    750.0 kVA 844.0 kVA

    600.0 kW 675.2 kW

    • Refer to ratings definitions on page 4.

    Ratings at 0.8 power factor.


    Technical Data

    Engine Make & Model:

    Perkins 4006TAG2A

    Alternator Model:

    LL7024L

    Base Frame Type:

    Heavy Duty FabriCAT-parts-partsed Steel

    Circuit Breaker Type:

    3 Pole ACB/MCCB

    Frequency:

    50 Hz 60 Hz

    Engine Speed: RPM

    1500 1800

    Fuel Tank Capacity: litres (US gal)

    1494 (394.7)

    Fuel Consumption: P730P1 l/hr (US gal/hr)

    149.8 (39.6) 167.0 (44.1)

    Fuel Consumption: P800E1 l/hr (US gal/hr)

    163.4 (43.2) 189.1 (50.0)

    P730P1 / P800E1


    Engine Technical Data

    Physical Data


    Manufacturer: Perkins

    Model: 4006TAG2A

    No. of Cylinders/Alignment: 6 / In Line

    Cycle: 4 Stroke

    Induction: Turbocharged

    Air To Air Charge Cooled

    Cooling Method: Water

    Governing Type: Electronic

    Governing Class: ISO 8528 G2

    Compression Ratio: 13.6:1

    Displacement: l (cu.in) 22.9 (1398.7)

    Bore/Stroke: mm (in) 160.0 (6.3)/190.0 (7.5)

    Moment of Inertia: kg m² (lb. in²) 10.61 (36256)

    Engine Electrical System:

    -Voltage/Ground: 24/Negative

    -Battery Charger Amps: 40

    Weight: kg (lb)

    - Dry: 2524 (5564)

    - Wet: 2663 (5871)


    Air System


    Air Filter Type: Replaceable

    Element Combustion Air Flow:

    m³/min (cfm) -Standby: 71.0 (2507) 73.0 (2578)

    -Prime: 64.0 (2260) 65.0 (2295)

    Max. Combustion Air Intake

    Restriction: kPa (in H2O) 3.7 (14.9) 3.7 (14.9)

    Radiator Cooling Air Flow:

    m³/min (cfm) 1134.0 (40047) 1326.0 (46827)

    External Restriction to

    Cooling Air Flow: Pa (in H2O) 250 (1.0) 250 (1.0)

    Cooling System 50 Hz 60 Hz

    Cooling System Capacity:

    l (US gal) 105.0 (27.7) 105.0 (27.7)

    Water Pump Type: Centrifugal

    Heat Rejected to Water & Lube Oil: kW (Btu/min)

    -Standby: 230.0 (13080) 243.0 (13819)

    -Prime: 191.0 (10862) 200.0 (11374)

    Heat Radiation to Room:

    kW (Btu/min) -Standby: 88.7 (5044) 98.9 (5624)

    -Prime: 83.7 (4760) 93.9 (5340)

    Radiator Fan Load: kW (hp) 26.0 (34.9) 44.0 (59.0)

    Cooling system designed to operate in ambient conditions up to 50°C (122°F).

    Contact your local FG Wilson dealer for power ratings at specific site conditions.

    Performance 50 Hz 60 Hz


    Engine Speed: RPM 1500 1800

    Gross Engine Power: kW (hp)

    -Standby: 711.0 (953.0) 759.0 (1018.0)

    -Prime: 646.0 (866.0) 684.0 (917.0)

    BMEP: kPa (psi)

    -Standby: 2481.0 (359.9) 2208.0 (320.2)

    -Prime: 2255.0 (327.0) 1989.0 (288.5)

    Regenerative Power: kW 70.0 75.0


    LubriCAT-parts-partsion System

    Oil Filter Type: Spin-On, Full Flow

    Total Oil Capacity l (US gal): 123.0 (32.5)

    Oil Pan l (US gal): 113.4 (30.0)

    Oil Type: API CG4 15W-40

    Cooling Method: Water


    Exhaust System 50 Hz 60 Hz

    Silencer Type: Level 1

    Silencer Model & Qty: SD250 (1)

    Pressure Drop Across Silencer System: kPa (in Hg) 1.20 (0.354) 0.22 (0.065)

    Silencer Noise Reduction Level: dB 20 16

    Max. Allowable Back Pressure: kPa (in. Hg) 6.0 (1.8) 6.0 (1.8)

    Exhaust Gas Flow: m³/min (cfm)

    -Standby: 180.0 (6357) 190.0 (6710)

    -Prime: 180.0 (6357) 190.0 (6710)

    Exhaust Gas Temperature: °C (°F)

    m³/min (cfm)

    -Standby: 430 (806) 430 (806)

    -Prime: 430 (806) 430 (806)


    Fuel System

    Fuel Filter Type: Replaceable Element Recommended

    Fuel: Class A2 Diesel

    Fuel Consumption: l/hr (US gal/hr)

    110% 100% 75% 50%

    Load Load Load Load

    P730P1

    50 Hz 164.0 (43.3) 149.8 (39.6) 114.8 (30.3) 81.6 (21.6)

    60 Hz 189.1 (50.0) 167.0 (44.1) 124.7 (32.9) 89.9 (23.7)

    P800E1

    50 Hz 163.4 (43.2) 124.7 (32.9) 87.9 (23.2)

    60 Hz 189.1 (50.0) 139.9 (37.0) 97.8 (25.8)

    (based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869, Class A2)

    P730P1 / P800E1


    Alternator Performance Data

    Data Item

    50 Hz 60 Hz

    415/240V

    400/230V

    380/220V

    480/277V

    380/220V

    440/254V

    Motor Starting Capability* kVA

    2096

    1962

    1789

    2307

    1514

    1977

    Short Circuit Capacity** %

    300

    300

    300

    300

    300

    300

    Reactances: Per Unit

    Xd X'd X''d

    2.800


    0.140


    0.110

    3.020


    0.150


    0.118

    3.340


    0.160


    0.131

    2.580


    0.130


    0.101

    4.040


    0.200


    0.158

    3.070


    0.150


    0.120

    Reactances shown are applicable to prime ratings

    • Based on 30% voltage dip. Improved motor starting capability is available with optional Permanent Magnet generator or AREP excitation.

    ** With optional Permanent Magnet generator or AREP excitation.


    Alternator Technical Data

    Physical Data Operating Data

    Manufacturer: FG WILSON

    Overspeed: RPM2250

    Model: LL7024L

    Voltage Regulation (steady state) (%): + /- 0.5

    No. of Bearings: 1

    Wave Form NEMA = TIF: 50

    Insulation Class: H

    Wave Form IEC = THF: 2.0%

    Winding Pitch Code: 2/3 - 6S

    Total Harmonic Content LL/LN: 4.0%

    Wires: 6

    Supression is in line with European Standard Radio Interference: EN61000-6

    Ingress Protection Rating: IP23

    Radiant Heat: kW (Btu/min)

    -50 Hz: 38.7 (2201)

    -60 Hz: 43.9 (2497)

    Excitation System: AREP

    AVR Model: R448

    P730P1 / P800E1


    Technical Data

    3 Phase Ratings and Performance at 50 Hz, 1500 RPM

    3 Phase Ratings and Performance at 60 Hz, 1800 RPM

    Voltage Prime Model Standby Model Voltage Prime Model Standby Model

    P730P1 P800E1 P730P1 P800E1


    kVA kW

    kVA kW


    kVA kW

    kVA kW

    415/240V

    730.0 584.0

    800.0 640.0

    480/277V

    750.0 600.0

    844.0 675.2

    400/230V

    730.0 584.0

    800.0 640.0




    380/220V

    730.0 584.0

    800.0 640.0

    380/220V

    735.0 588.0

    810.0 648.0




    440/254V

    - -

    - -

    Definitions


    Standby Rating

    These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).


    Prime Rating

    These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.


    Standard Reference Conditions

    Note: Standard reference conditions 27°C (80°F) Air Inlet Temp, 152.4m (500ft) A.S.L. 60% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.



    Weights and Dimensions


    Weights: kg (lb) Dimensions: mm (in

    Net (+ lube oil)

    6059 (13358)

    Length

    4280 (168.5)

    Wet (+ lube oil & coolant)

    6170 (13603)

    Width

    1912 (75.3)

    Fuel, lube oil & coolant

    6330 (13955)

    Height

    2277 (89.6)


    General Data

    Documents

    A full set of operation and maintenance manuals, circuit wiring diagrams, and commissioning/fault finding instruction leaflets.


    Generating Set Standards

    The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, VDE 0530, NEMA MG-1.22.