Sign In | Join Free | My himfr.com
Home > Perkins Diesel Generator >

50 Hz Perkins Diesel Generator , LL7024P , 1800rpm , Three Phase

    Buy cheap 50 Hz Perkins Diesel Generator , LL7024P , 1800rpm , Three Phase from wholesalers
     
    Buy cheap 50 Hz Perkins Diesel Generator , LL7024P , 1800rpm , Three Phase from wholesalers
    • Buy cheap 50 Hz Perkins Diesel Generator , LL7024P , 1800rpm , Three Phase from wholesalers
    • Buy cheap 50 Hz Perkins Diesel Generator , LL7024P , 1800rpm , Three Phase from wholesalers

    50 Hz Perkins Diesel Generator , LL7024P , 1800rpm , Three Phase

    Ask Lasest Price
    Brand Name : GSKA
    Model Number : JP-P900E1
    Price : Negotiable
    Delivery Time : 3-5 days on receipt of official sales contract
    Payment Terms : L/C,D/P,D/A, Alipay, West Union, TT. Cash,Paypal
    Supply Ability : 500 pieces per Month
    • Product Details
    • Company Profile

    50 Hz Perkins Diesel Generator , LL7024P , 1800rpm , Three Phase



    1, Engine Make & Model: Perkins 4006TAG3A

    2,Generating Set Model: P900E1

    3,Alternator Model: LL7024P

    4, Circuit Breaker Type: 3 Pole ACB/MCCB

    5, Frequency: 50 Hz / 60 Hz

    6,Cycle: 4 Stroke

    7, Engine Speed: 1500rpm/1800rpm

    8, Cooling Method: Turbo, Water/Air cooling

    9, Governing Type: Electronic

    10, Output Type: AC Three Phase

    10, No.of Cylinders/Alignment: 6 / In Line

    11,Base Frame Type: Heavy Duty FabriCAT-parts-partsed Steel


    LL7024P 50 Hz Perkins Diesel Generator , 4006TAG3A

    Output Ratings

    Generating Set Model

    * P900E1

    Prime* Standby*

    380-415V, 50 Hz

    800.0 kVA 900.0 kVA

    640.0 kW 720.0 kW

    480V, 60 Hz

    844.0 kVA 938.0 kVA

    675.2 kW 750.4 kW

    • Refer to ratings definitions on page 4.

    Ratings at 0.8 power factor.


    Technical Data

    Engine Make & Model:

    Perkins 4006TAG3A

    Alternator Model:

    LL7024P

    Base Frame Type:

    Heavy Duty FabriCAT-parts-partsed Steel

    Circuit Breaker Type:

    3 Pole ACB/MCCB

    Frequency:

    50 Hz 60 Hz

    Engine Speed: RPM

    1500 1800

    Fuel Tank Capacity: litres (US gal)

    1494 (394.7)

    Fuel Consumption: P800P1 l/hr (US gal/hr)

    163.0 (43.1) 188.3 (49.7)

    Fuel Consumption: P900E1 l/hr (US gal/hr)

    183.5 (48.5) 211.9 (56.0)

    P800P1 / P900E1


    Engine Technical Data


    Physical Data


    Manufacturer: Perkins

    Model: 4006TAG3A

    No. of Cylinders/Alignment: 6 / In Line

    Cycle: 4 Stroke

    Induction: Turbocharged Air To Air Charge Cooled

    Cooling Method: Water

    Governing Type: Electronic

    Governing Class: ISO 8528 G2

    Compression Ratio: 13.6:1

    Displacement: l (cu.in) 22.9 (1398.7)

    Bore/Stroke: mm (in) 160.0 (6.3)/190.0 (7.5)

    Moment of Inertia: kg m² (lb. in²) 10.61 (36256)

    Engine Electrical System:

    -Voltage/Ground: 24/Negative

    -Battery Charger Amps: 40

    Weight: kg (lb) - Dry: 2524 (5564)

    - Wet: 2663 (5871)


    Air System 50 Hz 60 Hz


    Air Filter Type: Replaceable

    Element Combustion Air Flow:m³/min (cfm)

    -Standby: 73.0 (2578) 78.0 (2755)

    -Prime: 69.0 (2437) 76.0 (2684)

    Max. Combustion Air Intake Restriction: kPa (in H2O) 3.7 (14.9) 3.7 (14.9)

    Radiator Cooling Air Flow: m³/min (cfm) 1134.0 (40047) 1326.0 (46827)

    External Restriction to Cooling Air Flow: Pa (in H2O) 250 (1.0) 250 (1.0)


    Cooling System 50 Hz 60 Hz


    Cooling System Capacity:l (US gal) 105.0 (27.7) 105.0 (27.7)

    Water Pump Type: Centrifugal

    Heat Rejected to Water & Lube Oil: kW (Btu/min)

    -Standby: 300.0 (17061) 320.0 (18198)

    -Prime: 270.0 (15355) 290.0 (16492)

    Heat Radiation to Room:kW (Btu/min)

    -Standby: 97.1 (5522) 106.0 (6028)

    -Prime: 91.1 (5181) 100.0 (5687)

    Radiator Fan Load: kW (hp) 26.0 (34.9) 44.0 (59.0)

    Cooling system designed to operate in ambient conditions up to 50°C (122°F).


    Performance 50 Hz 60 Hz

    Engine Speed: RPM 1500 1800

    Gross Engine Power: kW (hp)

    -Standby: 786.0 (1054.0) 839.0 (1125.0)

    -Prime: 705.0 (945.0) 759.0 (1018.0)

    BMEP: kPa (psi)

    -Standby: 2743.0 (397.9) 2440.0 (353.9)

    -Prime: 2461.0 (356.9) 2208.0 (320.2)

    Regenerative Power: kW 70.0 75.0


    LubriCAT-parts-partsion System

    Oil Filter Type: Spin-On, Full Flow

    Total Oil Capacity l (US gal): 123.0 (32.5)

    Oil Pan l (US gal): 113.4 (30.0)

    Oil Type: API CG4 15W-40

    Cooling Method: Water


    Fuel System

    Fuel Filter Type: Replaceable

    Element Recommended Fuel: Class A2 Diesel

    Fuel Consumption: l/hr (US gal/hr)


    110% 100% 75% 50%

    Load Load Load Load

    P800P1

    50 Hz 179.4 (47.4) 163.0 (43.1) 123.6 (32.7) 88.2 (23.3)

    60 Hz 211.9 (56.0) 188.3 (49.7) 138.9 (36.7) 96.3 (25.4)

    P900E1

    50 Hz 183.5 (48.5) 137.9 (36.4) 96.8 (25.6)

    60 Hz 211.9 (56.0) 154.6 (40.8) 105.1 (27.8)

    (based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869, Class A2)


    Exhaust System 50 Hz 60 Hz

    Silencer Type: Level 1

    Silencer Model & Qty: SD250 (1) Pressure Drop Across

    Silencer System: kPa (in Hg) 1.35 (0.399) 0.34 (0.100)

    Silencer Noise Reduction

    Level: dB 20 16

    Max. Allowable Back

    Pressure: kPa (in. Hg) 7.0 (2.1) 7.0 (2.1)

    Exhaust Gas Flow:

    m³/min (cfm)

    -Standby: 193.0 (6816) 209.0 (7381)

    -Prime: 193.0 (6816) 209.0 (7381)

    Exhaust Gas Temperature: °C (°F)

    m³/min (cfm)

    -Standby: 500 (932) 500 (932)

    -Prime: 500 (932) 500 (932)

    P800P1 / P900E1


    Alternator Performance Data

    Data Item

    50 Hz 60 Hz

    415/240V

    400/230V

    380/220V

    480/277V

    380/220V

    440/254V


    Motor Starting Capability* kVA


    2613


    2446


    2228


    2879


    1885


    2464

    Short Circuit Capacity** %

    300

    300

    300

    300

    300

    300

    Reactances: Per Unit

    Xd X'd X''d

    2.570


    0.120


    0.098

    2.770


    0.130


    0.105

    3.060


    0.140


    0.116

    2.430


    0.110


    0.092

    3.840


    0.180


    0.146

    2.890


    0.140


    0.110

    Reactances shown are applicable to prime ratings

    • Based on 30% voltage dip. Improved motor starting capability is available with optional Permanent Magnet generator or AREP excitation.

    ** With optional Permanent Magnet generator or AREP excitation.


    Alternator Technical Data

    Physical Data Operating Data

    Manufacturer: FG WILSON

    Overspeed: RPM 2250

    Model: LL7024P

    Voltage Regulation (steady state) (%): + /- 0.5

    No. of Bearings: 1

    Wave Form NEMA = TIF: 50

    Insulation Class: H

    Wave Form IEC = THF: 2.0%

    Winding Pitch Code: 2/3 - 6S

    Total Harmonic Content LL/LN: 4.0%

    Wires: 6

    Supression is in line with European Standard Radio Interference: EN61000-6

    Ingress Protection Rating: IP23

    Radiant Heat: kW (Btu/min)

    -50 Hz: 37.1 (2110)

    -60 Hz: 42.0 (2388)

    Excitation System: AREP

    AVR Model: R448

    P800P1 / P900E1


    Technical Data

    3 Phase Ratings and Performance at 50 Hz, 1500 RPM

    3 Phase Ratings and Performance at 60 Hz, 1800 RPM


    Voltage Prime Model Standby Model Voltage Prime Model Standby Model

    P800P1 P900E1 P800P1 P900E1


    kVA kW

    kVA kW


    kVA kW

    kVA kW

    415/240V

    800.0 640.0

    900.0 720.0

    480/277V

    844.0 675.2

    938.0 750.4

    400/230V

    800.0 640.0

    900.0 720.0




    380/220V

    800.0 640.0

    900.0 720.0

    380/220V

    835.0 668.0

    920.0 736.0




    440/254V

    - -

    - -


    Definitions

    Standby Rating

    These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).


    Prime Rating

    These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.


    Standard Reference Conditions

    Note: Standard reference conditions 27°C (80°F) Air Inlet Temp, 152.4m (500ft) A.S.L. 60% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.



    Weights and Dimensions


    Weights: kg (lb) Dimensions: mm (in)


    Net (+ lube oil)


    6259 (13799)


    Length


    4280 (168.5)

    Wet (+ lube oil & coolant)

    6370 (14043)

    Width

    1912 (75.3)

    Fuel, lube oil & coolant

    6530 (14396)

    Height

    2277 (89.6)

    General Data


    Documents

    A full set of operation and maintenance manuals, circuit wiring diagrams, and commissioning/fault finding instruction leaflets.


    Generating Set Standards

    The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, VDE 0530, NEMA MG-1.22.


    Warranty

    All equipment carries full manufacturer's warranty.



    Quality 50 Hz Perkins Diesel Generator , LL7024P , 1800rpm , Three Phase for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangdong ALI Testing Equipment Co,.Ltd
    *Subject:
    *Message: