Sign In | Join Free | My himfr.com
Home > Uninterruptible Power Supply >

Household Uninterruptible Power Supply UPS220V Output Tower

    Buy cheap Household Uninterruptible Power Supply UPS220V Output Tower from wholesalers
     
    Buy cheap Household Uninterruptible Power Supply UPS220V Output Tower from wholesalers
    • Buy cheap Household Uninterruptible Power Supply UPS220V Output Tower from wholesalers
    • Buy cheap Household Uninterruptible Power Supply UPS220V Output Tower from wholesalers
    • Buy cheap Household Uninterruptible Power Supply UPS220V Output Tower from wholesalers

    Household Uninterruptible Power Supply UPS220V Output Tower

    Ask Lasest Price
    Brand Name : GSKA
    Model Number : UPS uninterruptible power supply
    Price : negotiation
    Supply Ability : 10000 Set / Sets per Month
    Delivery Time : 7-10working days after received deposit
    • Product Details
    • Company Profile

    Household Uninterruptible Power Supply UPS220V Output Tower

    Household Uninterruptible Power Supply UPS220V Output Tower


    Matters needing attention:


    Because of the particularity of its inverter and battery work, the installation and use of UPS power supply must have a set of strict and scientific operating procedures, in order to improve the stability of work, reduce the failure rate of equipment, and truly achieve uninterrupted power supply of equipment.


    (1) The installation environment of the UPS power supply should be protected from direct sunlight and have enough ventilation space to ensure that the operating temperature is not higher than 25 ° C. If the operating temperature exceeds 25 ° C, the battery life is reduced by about half for every 10 ° C increase in temperature rise.


    (2) It is not suitable to use high-power thyristor load, thyristor bridge rectifier or half-wave rectifier load at the output end of the UPS power supply, which is easy to cause the inverter's final drive transistor to be burned.


    (3) Strictly follow the correct startup and shutdown sequence to avoid large fluctuations in the voltage output of the UPS power supply when the load suddenly increases or decreases, so that the UPS power supply cannot work normally.


    (4) Do not frequently turn off or on the UPS power supply. Generally, wait at least 30 seconds after turning off the UPS power supply. The cause of frequent UPS power failures is that users start or shut down frequently, and the UPS power supply switches between inverter power supply and bypass power supply with load.


    (5) Practice has proved that for the vast majority of UPS power supplies, it is the best working mode to control the load within the range of 50%~60% rated output power. It is forbidden to use over load. The manufacturer suggests that the maximum starting load of UPS power supply should be controlled within 80%. If overload is used, it will often breakdown the inverter triode in the inverter state. Not too light load operation, this situation is easy to cause battery failure because the battery discharge current is too small.


    (6) Regularly maintain the UPS power supply: observe the status of the working indiCAT-parts-partsor, remove dust, measure the voltage of the battery, replace the unqualified battery, check the running status of the fan, and detect and adjust the system parameters of the UPS.


    (7) UPS power supply is more suitable for with micro capacitive load, not suitable for charged inductive load, such as air conditioning, motor, electric drill, fan, etc. If the UPS power load is resistive or inductive, reduce the load to avoid overload.

    Product Parameters:
    Model
    GSKA-500
    GSKA-800
    GSKA-1000
    GSKA-1500
    GSKA-2000
    GSKA-2500
    GSKA-3000
    GSKA-5000
    Rated Capacity
    500VA
    800VA
    1000VA
    1500VA
    2000VA
    2500VA
    3000VA
    5000VA
    Rated Power
    300W
    500W
    700W
    1050W
    1400W
    1800W
    2100W
    3500W
    Transformer
    Toroidal transformer
    Interface
    LED graphic
    Display status
    working&loading&battery
    Working mode
    PV(Photovoltaic priority)/AC(AC priority) optional
    Input
    Voltage
    140-275Vac
    Frequency
    45-65Hz
    Output
    Voltage
    220Vac±3% for inveter; 195v-240V for avr
    Frequency
    50/60Hz ± 0.3Hz, subject to the main
    Wave Form
    Pure sine wave
    Wave Distortion
    ≤3%
    Protection
    overload/high temperature/output high voltage /output low voltage/
    battery low voltage shortcircuit/over-charge/over-discharge/reversed polarity(optional)
    Transfer Time
    ≤4ms
    Battery Voltage
    12VDC
    24VDC
    48VDC
    Charge Voltage
    13.6V±0.3V
    27.2V±0.6V
    54.5V±1V
    Low Battery Voltage Limit
    10.9V±0.3V
    21.8V±0.5V
    42V±1V
    Protections Battery Low Voltage Protection Point
    10.2V±0.3V
    20.5V+0.5V
    41V±1V
    Charge Current
    Max.10A/15A/20A optional
    Environmental
    Operating Temperature
    0~40℃
    Relative Humidity
    10%~90%RH,non-condensing
    Storage Temperature
    -15-45℃
    Packing
    Machine Size(mm)
    280x144x213
    385x190x320
    Qty/Ctn
    4
    4
    2
    2
    1
    1
    1
    1
    Carton Size(mm)
    785x305x240
    415x410x245
    410x290x320
    CartonG.W.(kg)
    22
    26
    17.2
    19.1
    410x290x321
    Quality Household Uninterruptible Power Supply UPS220V Output Tower for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangdong ALI Testing Equipment Co,.Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)