Sign In | Join Free | My himfr.com
Home > Small Gasoline Powered Generator >

Portable Compact Gasoline Generator Forced Air Cooling 110/220V

    Buy cheap Portable Compact Gasoline Generator Forced Air Cooling 110/220V from wholesalers
     
    Buy cheap Portable Compact Gasoline Generator Forced Air Cooling 110/220V from wholesalers
    • Buy cheap Portable Compact Gasoline Generator Forced Air Cooling 110/220V from wholesalers
    • Buy cheap Portable Compact Gasoline Generator Forced Air Cooling 110/220V from wholesalers

    Portable Compact Gasoline Generator Forced Air Cooling 110/220V

    Ask Lasest Price
    Brand Name : GSKA
    Model Number : SF5600i/SF3600i
    Price : Negotiable
    Payment Terms : L/C,D/P,D/A, Alipay, West Union, TT. Cash,Paypal
    Supply Ability : 500 pieces per Month
    Delivery Time : one weeks on receipt of official sales contract
    • Product Details
    • Company Profile

    Portable Compact Gasoline Generator Forced Air Cooling 110/220V

    Portable Compact Gasoline Generator Forced Air Cooling 110/220V


    common fault:


    The no-load voltage is too high:


    (1) Automatic voltage regulator is out of control. The excitation winding current of no-load exciter is too large. Check the automatic voltage regulator.


    (2) The setting voltage is too high to reset the voltage.


    Excitation current of exciter:


    (1) The rectifier element has one or two components in the positive and negative circuit, check with a multimeter, replace the damaged components.


    (2) The main generator or exciter part of the excitation winding short circuit, measure the DC resistance value of each pole coil. Replace the coil with a short circuit fault.


    Steady-state voltage adjustment rate:


    Automatic voltage regulator has a fault check and troubleshoot.


    High vibration:


    (1) Poor docking with prime mover check and correct docking. After the bolts are fastened, ensure that the generator and the prime mover axis are straight and concentric.


    (2) The rotor dynamic balance is not good, occurs after the rotor is rewound, should find the positive dynamic balance.


    (3) Short-circuit of the excitation winding of the main generator measure the DC resistance of each pole and find out the short-circuit fault point. Replace the coil.


    (4) Bearing damage, generally bearing cover overheating phenomenon, replace the bearing.


    (5) If the prime mover is faulty, check the prime mover.


    overheating:


    (1) The generator is overloaded, so that the load current and voltage do not exceed the rated value.


    (2) The load power factor is too low, adjust the load, so that the excitation current does not exceed the rated value.


    (3) If the speed is too low, adjust the speed to the rated value.


    (4) There is a short circuit in some windings of the generator. Find out the short circuit and correct or replace the coil.


    (5) The air duct is blocked, the obstacles are removed, the motor is dismantled, and the air duct is thoroughly blown.


    Product Description:


    DIGITAL INVERTER GENERATOR 3.3HP/2KW
    Model Number8896219
    Number of phases1 ph
    Maximum power2kw
    Rated power1.85kw
    Voltage/frequency230v/50hz
    Power factor1
    Engine
    Max.engine power2.5kw(3.3hp/5500/min)
    Displacement80cc
    Startingrecoil
    Consumptionapprox. 0.9 1/kwh
    Tank volume4.5 l
    Generator
    Type of generatormultipole,digital control,inverter.
    AC rated current8.0A/230V
    DC rated current8.3A/12V
    Weight21.6kg
    Dimension42x52x29cm


    Quality Portable Compact Gasoline Generator Forced Air Cooling 110/220V for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangdong ALI Testing Equipment Co,.Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)